Local_n> CHANGE DEDICATED TCP 192.168.0. Each MSS would have to be configured to both send packets to and accept packets from the other MSS.Ĭonfiguration for MSS-VIA and MSS4 is as follows: Com Port Redirector (CPR) v4 and TruPort Technology The fourth generation of Com Port. Com Port Redirector receives the data and presents it to the control application as if it came from a COM port via a local serial connection. When the UDP protocol is used, there is no connection each MSS must be told explicitly which hosts it is allowed to accept packets from. the serial port of the device server is transmitted back to the application software on the PC via Ethernet. 4:Configuration Describes how to configure Com Port Redirector and the serial devices with which it communicates. 3: Installing Com Port Redirector Provides instructions for installing Com Port Redirector. You can also create a UDP-connection between the MSS device servers. 2: Introducing Com Port Redirector Provides an overview of Com Port Redirector and a Quick Start for getting the application up and running. In the example above we established a TCP connection between two MSS device servers. The configuration of MSS_B ensures that it is always available to accept connections from MSS_A. EDS3000PR leverages the Lantronix Com Port Redirector virtualization software, allowing existing applications to work with the EDS with no code modifications. The configuration of MSS_A ensures that it will automatically connect to MSS_B each time it is booted. Note: If the device servers are on different IP subnets, the default gateway on each unit will have to be configured with the Change Server Gateway command. See below an example of the MSS100 web interface configuration: You can also configure the MMS units thru their web interface. This connection passes data only, status signals such as dsr/dtr/cts/rts are not passed between the MSSs. Power cycle the two MSS units and the "virtual serial line" will be created. It allows legacy equipment to be used securely throughout an organization. These commands will create a RAW (8-bit clean) TCP connection between the serial ports of the two MSSs. Secure Com Port Redirector by Lantronix Secure Com Port Redirector (SCPR) is a software solution that establishes secure communication between a computer and peripheral devices attached to a serial port. Local_n> CHANGE DEDICATED TCP 192.168.5.10:3001TĪCCESS on MSS B must be DYNAMIC or REMOTE for the connection to succeed. Password> system >", indicating that you are now a privileged user, where n is either 1 if you are configuring the MSS through the serial interface, or some larger number if you connected to the CLI via telnet. To do this enter on both MSS units the following: To be able to configure the settings below you need to become a privileged user. are correct on the MSSs for the serial device. You will also need to insure that the port parameters such as speed, number of bits, flow control etc. Note the reference to the MSSs by their letter. The commands necessary for this configuration to automatically establish this connection are as follows. Can we use 2 serial servers connected over the LAN that act as a serial cable (when turned on they would make a connection via the LAN)? We can't make any changes to the device, but we know the baudrate, number of bits, stopbits, etc.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |